รายละเอียดเอกสาร

สิ่งแวดล้อม มลภาวะ ของเสีย

เอกสารมาตรฐาน

สหรัฐอเมริกา

ASTM

D5996-16

Standard Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography

2016

7

ASTM Vol.11.01 (2023)

This test method covers on-line analysis of high-purity water by the ion chromatography technique. This test method is applicable for measuring various anionic contaminants in high-purity water, typically in the range of 0.01 to 100 μg/L. This test method is used to determine the concentration of acetate, formate, chloride, fluoride, phosphate, nitrate, and sulfate in a continuously flowing sample. The range of the test method is only as good as the reagent water available for preparing standards. At extremely low concentrations, <1.0 μg/L, preparing standards is difficult, and extra care must be taken in their preparation. The sample may have to be conditioned from higher pressures and temperatures to conditions that are suitable for use by on-line instruments...