ผลิตภัณฑ์อาหาร เครื่องดื่ม อาหารสัตว์
บทความ
สหราชอาณาจักร
ไม่ระบุ
Multi-Allergen Quantification in Food Using Concatemer-Based Isotope Dilution Mass Spectrometry: An Interlaboratory Study
2023
13
Journal of AOAC INTERNATIONAL Vol. 106, No. 4, July-August 2023, p. 886–898
Background
Food allergen analysis is essential for the development of a risk-based approach for allergen management and labeling. MS has become a method of choice for allergen analysis, even if quantification remains challenging. Moreover, harmonization is still lacking between laboratories, while interlaboratory validation of analytical methods is necessary for such harmonization.
Objective
This interlaboratory study aimed to evaluate the potential of MS for food allergen detection and quantification using a standard addition quantification strategy and a stable isotope-labeled (SIL) concatemer as an internal standard.
Methods
In-house-produced test material (cookies), blank and incurred with four allergens (egg, milk, peanut, and hazelnut), allergen standards, an internal standard, and the complete methodology (including sample preparation and ultra-HPLC–MS/MS method) were provided to nine laboratories involved in the study. Method sensitivity and selectivity were evaluated with incurred test material and accuracy with spiked test material. Quantification was based on the standard addition strategy using certified reference materials as allergen protein standards and a SIL concatemer as an internal standard.
Results
All laboratories were able to detect milk, hazelnut, and peanut in the incurred cookies with sufficient sensitivity to reach the AOAC INTERNATIONAL Standard Method Performance Requirements (SMPR® 2016.002). Egg detection was more complicated due to food processing effects, yet five laboratories reached the sensitivity requirements. Recovery results were laboratory-dependent. Some milk and hazelnut peptides were quantified in agreement with SMPR 2016.002 by all participants. Furthermore, over 90% of the received quantification results agreed with SMPR 2016.002 for method precision.
Conclusion
The encouraging results of this pioneering interlaboratory study represent an additional step towards harmonization among laboratories testing for allergens.
Highlights
In this pioneering interlaboratory study, food allergens were analyzed by MS with characterized incurred and spiked test materials, calibrated with a certified reference material, and a single SIL concatemer used as an internal standard.